Report a problem
Judy's Book takes violations of our Terms of Use very seriously. We encourage
you to read through our
Terms of Use
before filling report with us.
After careful review, we may remove content or replace a content warning page before
viewing content deemed offensive, harmful, or dangerous.
Additionally, we are aware that there may be content on Judy's Book that is personal
in nature or feels invasive. Please note that Judy's Book is a provider of content
creation tools, not a mediator of content. We allow our users express their opinions,
but we don't make any claims about the content of these pages. We strongly believe
in freedom of expression, even if a review contains unappealing or distasteful
content or present negative viewpoints. We realize that this may be frustrating,
and we regret any inconvenience this may cause you. In cases where contact information
for the author is listed on the page, we recommend that you work directly with this
person to have the content in question removed or changed.
Here are some examples of content we will not remove unless provided with a court
order:
Personal attacks or alleged defamation
Political or social commentary
Distasteful imagery or language
If we've read the Terms of Use and believe that this review below violates our Terms
of Use, please complete the following short form.
Businiess name:
Hanks SVC
|
Review by:
citysearch c.
|
Review content:
My goal was to install an AC system using the new CFC-free R-410A refrigerant rather than the old R-22 refrigerant, which is harmful to the atmosphere and will be phased out in a few years. I also wanted to get a high-efficiency system that would qualify for the highest-level rebate from Austin Energy ($480) and the $300 Federal tax credit. The minimum requirements for this are 15 SEER and 12.5 EER. It turned out after much searching (both by me and Austin Energy!) that only two manufacturers currently make systems satisfying these criteria: Rheem and Lennox. Though I had planned on getting the standard 3 proposals, I ended up having to get 6 proposals from 4 different contractors because I found the first three contractors unsatisfactory. The EER (Environmental Efficiency Rating) is tricky to compute because it depends on the entire system (condenser, coil and furnace), and it turned out that the first 5 proposals failed to meet it when all was said and done. Furthermore, I discovered a very important issue related to switching from R-22 to R-410A refrigerants: The copper tubes leading from the condenser to the coil, called the ""lineset,"" must be either replaced or very carefully cleaned under high vacuum conditions. None of the first three contractors even mentioned this, and I only learned about it from the fourth contractor, Hank's Service! If the tubes are not replaced, or at least washed out properly under high vacuum (and it seems they would not have been by the first three contractors since no mention was made of the topic even though replacing the tubes, which is recommended, incurs an extra cost), this is likely to damage the new condenser. The proposal I got from Hank's Service also came in much lower than the others. The installer, Bobby, was very experienced and took his time doing the job right.
Pros: Prompt, competent service, yet the least expensive of 6 proposals!
|
Reasons for reporting (512 characters left):
|
Reasons are required.
|
or
Cancel
|